Biostrings 2.74.1
This document presents some basic and simple tools for dealing with the oligonucleotide microarray reporter sequence information in the Bioconductor probe packages. This information is used, for example, in the gcrma package.
Probe packages are a convenient way for distributing and storing the probe sequences (and related information) of a given chip.
As an example, the package hgu95av2probe provides microarray reporter sequences for Affymetrix’ HgU95a version 2 genechip, and for almost all major Affymetrix genechips, the corresponding packages can be downloaded from the Bioconductor website. If you have the reporter sequence information of a particular chip, you can also create such a package yourself. This is described in the makeProbePackage vignette of the AnnotationForge package.
This document assumes some basic familiarity with R and with the design of the AffyBatch class in the affy package, Bioconductor’s basic container for Affymetrix genechip data.
First, let us load the Biostrings package and some other packages we will use.
library(Biostrings)
library(hgu95av2probe)
library(hgu95av2cdf)
Help for the probe sequence data packages can be accessed through
?hgu95av2probe
One of the issues that you have to deal with is that the probe packages do not provide the reporter sequences of all the features present in an AffyBatch. Some sequences are missing, some are implied; in particular, the data structure in the probe packages does not explicitly contain the sequences of the mismatch probes, since they are implied by the perfect match probes. Also, some other features, typically harboring control probes or empty, do not have sequences. This is the choice that Affymetrix made when they made files with probe sequences available, and we followed it.
Practically, this means that the vector of probe sequences in a probe package
does not align 1:1 with the rows of the corresponding AffyBatch; you need to
keep track of this mapping, and some tools for this are provided and explained
below (see Section 2.2). It also means that some functions from the
affy package, such as pm
, cannot be used when the sequences of
the probes corresponding to their result are needed; since pm
reports the
intensities, but not the identity of the probes it has selected, yet the latter
would be needed to retrieve their sequences.
Let us look at some basic operations on the sequences.
DNA sequences can be reversed and/or complemented with the reverse
,
complement
and reverseComplement
functions.
?reverseComplement
pm <- DNAStringSet(hgu95av2probe)
dict <- pm[3801:4000]
pdict <- PDict(dict)
m <- vcountPDict(pdict, pm)
dim(m)
## [1] 200 201800
table(rowSums(m))
##
## 1 2 3
## 179 15 6
which(rowSums(m) == 3)
## [1] 77 79 80 81 82 83
ii <- which(m[77, ] != 0)
pm[ii]
## DNAStringSet object of length 3:
## width seq
## [1] 25 TCGTCATCAGGTGCATAGCAAGTGA
## [2] 25 TCGTCATCAGGTGCATAGCAAGTGA
## [3] 25 TCGTCATCAGGTGCATAGCAAGTGA
The base content (number of occurrence of each character) of the sequences can
be computed with the function alphabetFrequency
.
bcpm <- alphabetFrequency(pm, baseOnly=TRUE)
head(bcpm)
## A C G T other
## [1,] 1 10 6 8 0
## [2,] 5 5 5 10 0
## [3,] 6 4 3 12 0
## [4,] 4 7 8 6 0
## [5,] 4 5 8 8 0
## [6,] 2 7 6 10 0
alphabetFrequency(pm, baseOnly=TRUE, collapse=TRUE)
## A C G T other
## 1250858 1235532 1186629 1371981 0
nc = hgu95av2dim$NCOL
nc
## [1] 640
nr = hgu95av2dim$NROW
nr
## [1] 640
Each column of an AffyBatch corresponds to an array, each row to a certain
probe on the arrays. The probes are stored in a way that is related to their
geometrical position on the array. For example, the hgu95av2 array is
geometrically arranged into 640 columns and 640 rows. We call the column
and row indices the x
- and y
-coordinates, respectively. This results in
640 ⨉ 640 = 409600 probes of the AffyBatch;
we also call them indices. To convert between x
-and y
-coordinates and
indices, you can use the functions xy2indices
and indices2xy
from the
affy package.
The sequence data in the probe packages is addressed by their x
and
y
-coordinates. Let us construct a vector abseq
that aligns with the indices
of an hgu95av2 AffyBatch and fill in the sequences:
library(affy)
abseq = rep(as.character(NA), nc*nr)
ipm = with(hgu95av2probe, xy2indices(x, y, nc=nc))
any(duplicated(ipm)) # just a sanity check
## [1] FALSE
abseq[ipm] = hgu95av2probe$sequence
table(is.na(abseq))
##
## FALSE TRUE
## 201800 207800
The mismatch sequences are not explicitly stored in the probe packages. They are
implied by the match sequences, by flipping the middle base. This can be done
with the pm2mm
function defined below. For Affymetrix GeneChips the length of
the probe sequences is 25, and since we start counting at 1, the middle position
is 13.
mm <- pm
subseq(mm, start=13, width=1) <- complement(subseq(mm, start=13, width=1))
cat(as.character(pm[[1]]), as.character(mm[[1]]), sep="\n")
## TGGCTCCTGCTGAGGTCCCCTTTCC
## TGGCTCCTGCTGTGGTCCCCTTTCC
We compute imm
, the indices of the mismatch probes, by noting that each
mismatch has the same x
-coordinate as its associated perfect match, while its
y
-coordinate is increased by 1.
imm = with(hgu95av2probe, xy2indices(x, y+1, nc=nc))
intersect(ipm, imm) # just a sanity check
## numeric(0)
abseq[imm] = as.character(mm)
table(is.na(abseq))
##
## FALSE TRUE
## 403600 6000
See Figures 1-3 for some applications of the probe sequence information to preprocessing and data quality related plots.